![]() Schneider D, Marquardt P, Zwahlen M, Jung RE. Within the limitations of this study, Anatomage-Invivo5© CAD/CAM surgical guides can be reliable tools to accurately place implants immediately after extraction. In addition, this study was limited to tooth supported guides which have been shown to be the most accurate of Conclusion DiscussionĮrrors have been reported in the literature for all systems providing such tool.6,7,8 A meta-regression analysis reported by Schneider et al.2 revealed a mean deviation at the entry point of 1.07mm, at the apex of 1.63, and an overall mean error in angulation of 5.261.2 Although this pilot study reports lower deviations, our sample was not large enough to compare to previous reports. ![]() The mean deviation at the crest was 0.67mm, the mean deviation at the apex was 0.88mm, and the mean deviation of the axis was 2.30 degrees. ![]() Nine implants in nine patients were included in this study. Records between 2012-2014 were gathered for patients who had immediately placed implants using Anatomage invivo 5 CAD/CAM surgical guides with both pre and post-op CBCT images on file. To assess the accuracy of a single, immediate implant placements using Anatomage-Invivo5© CAD/CAM surgical guides.